    J41B NRS Ammonia Globe Valve

    Product overview

    Product model: J41B
    Nominal diameter: DN15 ~ DN300
    Nominal pressure: PN16 ~ PN25
    Applicable medium: liquid, gas, ammonia, nitrogen, hydrogen
    Applicable temperature: -10℃-150℃
    Body material: cast iron, cast steel
    Drive mode: manual, gear drive, electric, pneumatic, etc
    Design and manufacture: GB12235
    Structure length: GB12221
    Flange size: GB9113 JB79
    Pressure - temperature: GB9131
    Test - inspection: GB/T13927 JB/T9092

    J41B NRS Ammonia Globe Valve product details

    J41B NRS Ammonia Globe Valve structural characteristics and uses
     1, through the flange for the square structure, the stem rod connection. 
     2, the valve body sealing surface using ball convex shape, and the valve to line seal. 
     3, the sealing surface with Babbitt, sealing performance, long service life.


    The J41B NRS Ammonia Globe Valve produced and sold by Baigang Valve Group often uses oxygen, nitrogen, hydrogen, argon and other gases.These gases are generally stored in a special high pressure gas.When in use, the gas pressure is reduced to the range required by the experiment through the ammonia cut-off valve, and then the gas is input into the use system through other control valves.Commonly used pressure reducing valve for ammonia cut-off valve, referred to as ammonia valve.


    J41B NRS Ammonia Globe Valve performance specifications

    Nominal pressure PN (MPA)

    Test pressure PS (MPa)

    Suitable media

    Applicable temperature (℃)

    2.5

    3.8

    Ammonia, 
    ammonia and other 
    NH3

    Babbitt alloy 
     -40 ℃ 
    + 150 ℃

    PTFE 
    -40 ℃ 
    +200 ℃

    4.0

    6.4


    J41B NRS Ammonia Globe Valve main size and weight:

    DN (mm)

    Size (mm)

    L

    D

    D1

    D2

    D4

    b

    f

    f1

    Z-φd

    turn off

    open

    D3

    10

    130

    90

    60

    40

    35

    16

    2

    4

    4-φ14

    165

    185

    110

    15

    130

    95

    65

    45

    40

    16

    2

    4

    4-φ14

    165

    185

    110

    20

    150

    105

    75

    55

    51

    18

    2

    4

    4-φ14

    170

    200

    120

    25

    160

    115

    85

    65

    58

    18

    2

    4

    4-φ14

    197

    210

    120

    32

    180

    135

    100

    78

    66

    20

    2

    4

    4-φ18

    199

    213

    140

    40

    200

    145

    110

    85

    76

    20

    3

    4

    4-φ18

    248

    264

    160

    50

    230

    160

    125

    100

    88

    22

    3

    4

    4-φ18

    265

    295

    180

    65

    290

    180

    145

    120

    110

    24

    3

    4

    8-φ18

    310

    349

    220

    80

    310

    195

    160

    135

    121

    26

    3

    4

    8-φ18

    340

    357

    240

    100

    350

    230

    190

    160

    150

    30

    3

    4.5

    8-φ23

    380

    413

    280

    125

    400

    270

    220

    188

    176

    32

    3

    4.5

    8-φ25

    430

    451

    320

    150

    480

    300

    250

    218

    204

    32

    3

    4.5

    8-φ25

    505

    492

    360

    200

    600

    360

    310

    278

    260

    34

    3

    4.5

    12-φ25

    550

    806

    400

    250

    650

    425

    370

    335

    31

    36

    3

    4.5

    12-φ30

    730

    880

    450

    300

    750

    485

    430

    390

    364

    40

    3

    4.5

    16-φ30

    -

    995

    550


    J41B NRS Ammonia Globe Valve appearance and working principle

     Ammonia valve high pressure chamber and the cylinder connection, low pressure chamber for gas exports, and access to the use of the system. Indication of high pressure gauge is the pressure of gas stored in the cylinder. Low pressure gauge outlet pressure can be controlled by adjusting screw. 
     Open the cylinder main switch when using, then turn the low pressure gauge pressure adjusting screw clockwise to compress the main spring and drive the diaphragm, spring pad and ejector to open the valve. Such imports of high-pressure gas from the high-pressure chamber after throttling decompression into the low-pressure chamber, and through the exit leading to the working system. Turn the adjusting screw to change the opening height of the valve to regulate the passage of high-pressure gas and achieve the desired pressure value. 
     Ammonia cut-off valves are equipped with safety valves. It is to protect the ammonia valve and make it safe to use the device, but also the ammonia valve failure signal device. If due to the valve pad, valve damage or for other reasons, resulting in the pressure on the outlet and rise above a certain allowable value, the safety valve will automatically open the exhaust.

    Fifth, the use of
     (1) according to the different requirements of use, ammonia valve has many specifications. Most of the highest import pressure, the minimum import pressure of not less than 2.5 times the outlet pressure. Export pressure specifications more generally, the maximum outlet pressure.   
     (2) Ammonia valve should be installed to determine whether the connection specifications consistent with the use of the system connector. Ammonia globe valve with hemispherical connection, by tightening the nut so that the two completely match. Therefore, the use of the two hemispherical surfaces should be kept clean to ensure a good airtight effect. Use high-pressure gas to blow off the dust before installation. If necessary, PTFE and other materials can also be used for gaskets. 
     (3) ammonia valve should be prohibited from contact with grease, so as to avoid fire accidents. 
     (4) stop working, the relief valve should be more than air net, and then loosen the adjustment screw to prevent long-term compression of the elastic deformation. 